| Several
publications discuss the advantages of visual field analysis as an
integral part of routine eye examinations. This equipment must be
capable of performing rapid screening and should have the ability to
provide more detailed quantitative information through additional
test procedures. Multiple stimulus supra-threshold static screening
is a well established technique and is the principle of operation of
the Optoscan ‘Plus’. The instrument can perform a primary
screening of the central visual field in under two minutes per eye,
in addition to more detailed evaluation of
defects. |
|
| |
|
|
"screening in under two
minutes" |
|
|
|
|
|
 |
|
The Optoscan
Scanner 'Plus' has received numerous awards for
its innovative simplicity...
|
 |
| 1994 |
SABS Design
Institute Award for outstanding Engineering
Design |
| 1997 |
SABS Design for
Development Award, for exemplifying "the concept that
good design is a major contributing factor in offering
solutions to the various problems facing developing
communitites" |
| 1997 |
Engineering
Council / Week "Top Products '97"
Award | | | |
|
The Optoscan
‘Plus’ is a fully portable primary field screener and can also be
used to perform more in-depth evaluation of a scotoma. It is a
supra-threshold instrument but ideal for routine screening. Features
include a check for eye fixation on the central target; automatic power
saving; and the control unit can also be optionally connected to a
personal computer for test and patient record keeping. A software package,
called 'SoftScan' is supplied on CD to facilitate this. |
|
"a fully portable primary field
scanner" |
|
| |
|

|
|
A total of
74 LED's are displayed to the patient in 20 asymmetric patterns. Each of
the patterns, when selected by the operator, displays a different array of
stimuli. The light stimuli are positioned at strategic positions between 5
and 25 degrees of the visual field. The intensity of the stimuli increases
towards the periphery to compensate for the normal gradient of sensitivity
across the retina. The patient is required to fixate the eye being tested
on a central yellow stimulus, or a light cross-hair. A stimulus is also
positioned within each of the optic nerve blind areas. These enable the
operator to ascertain whether the patient is fixating correctly on the
central target.
|
|
"patient and user
friendly" |
|

The
patient viewing unit is either mounted in an adjustable table stand or
held up to the eye by the patient. Test lenses may be fitted to the
eyepiece in order to correct for presbyopia or astigmatism. An on-board
memory is used to record the unseen stimuli which can be recalled at any
time during or at the conclusion of the test. The
SoftScan program facilitates the accurate keeping of both patient details
and test records.
The Optoscan
‘Plus’ is the most affordable supra-threshold field screener
available and is both patient and user friendly. It is extremely accurate
in the detection of scotoma indicating glaucoma, diabetes and other
pathology. |